Home / Charging cost by state / Charging speed by amps

Tesla charging speed by amps and breaker size: Wall Connector, NEMA 14-50 and 120 V

Tesla's Gen 3 Wall Connector manual lists a maximum of 48 amps, 11.5 kW at 240 V, on a 60 amp breaker, down to 12 amps on a 15 amp breaker. Tesla's Mobile Connector manual lists 32 amps (7.6 kW) on a NEMA 14-50 outlet and 12 amps (1.3 kW) on a standard 120 V outlet. For a 2026 Model Y that is about 36 to 48, 24 to 32 and 4 to 5 miles of EPA range per hour, if the car accepts the full rate. Not every trim does: in EPA's own 240 V test the 2026 Model Y trims drew 7.7 to 11.0 kW on average.

Tesla's own figures for the Wall Connector at every breaker size and the Mobile Connector on every outlet adapter, turned into miles of range per hour and hours to charge for each Tesla with EPA's ratings. The amps and kW are copied from Tesla's manuals; nothing is assumed about your car's onboard charger.

Tesla Wall Connector: amps and speed by breaker size

Tesla Wall Connector output by circuit breaker, with miles of range per hour
Breaker, ampsMax output, ampskW at 240 VModel 3 2026, mi/hModel Y 2026, mi/hModel S 2026, mi/hModel X 2026, mi/hCybertruck 2026, mi/hCost per hour, North Dakota to Hawaii
604811.538 to 4836 to 4832 to 4334 to 3627$1.43 to $5.34
50409.632 to 4030 to 4027 to 3628 to 3022$1.20 to $4.46
40327.625 to 3224 to 3221 to 2822 to 2418$0.95 to $3.53
30245.719 to 2418 to 2416 to 2117 to 1813$0.71 to $2.65
20163.813 to 1612 to 1611 to 1411 to 129$0.47 to $1.76
15122.89 to 129 to 128 to 108 to 97$0.35 to $1.30

Breaker, amps and kW: Tesla Gen 3 Wall Connector manual (published January 15, 2020, revision 1.0), "Circuit Breaker Rating / Maximum Output". Miles per hour are the range across each model's 2026 trims, kW x 100 / EPA kWh per 100 miles, if the car accepts that rate. Cost per hour = kW x the average residential price in North Dakota (lowest) and Hawaii (highest).

Tesla's manual adds: "Some Tesla vehicles may draw less current than the max output. Actual charging rate depends on Wall Connector output and onboard charger in the vehicle." The install cost of a Wall Connector or a 240 V outlet is on the Wall Connector install cost page.

Tesla Mobile Connector: amps and speed by outlet

Tesla Mobile Connector output by outlet adapter, with miles of range per hour
Outlet adapter (NEMA)VoltsAmpskWModel 3 2026, mi/hModel Y 2026, mi/hModel S 2026, mi/hModel X 2026, mi/hCybertruck 2026, mi/h
5-20120161.76 to 75 to 75 to 654
5-15120121.34 to 54 to 54 to 543
14-50, 6-50240327.625 to 3224 to 3221 to 2822 to 2418
14-30, 10-30240245.719 to 2418 to 2416 to 2117 to 1813
6-20240163.813 to 1612 to 1611 to 1411 to 129
6-15240122.89 to 129 to 128 to 108 to 97

Adapter, amps and kW: Tesla Gen 2 Mobile Connector owner's manual (publication date 2024/08/28), "Charging Rate Reference". The manual says the Mobile Connector "automatically detects the attached adapter and sets the appropriate current draw", and that some units do not include the 14-50 adapter.

Every 2026 Tesla: miles per hour and hours to charge

Charging speed and time for every 2026 Tesla trim
TrimEPA kWh per 100 milesMi/h, Wall Connector 11.5 kWMi/h, NEMA 14-50 7.6 kWMi/h, 120 V 1.3 kWkWh, empty to fullHours, 11.5 kWHours, 7.6 kWHours, 1.3 kWEPA hours at 240 VEPA 240 V test, average kW
Model 3 Standard RWD2448325776.710.159.312.16.4
Model 3 Premium RWD2546305917.911.969.811.77.8
Model 3 Premium AWD2644295907.811.869.211.77.7
Model 3 Performance3038254938.112.271.3127.7
Model 3 Performance AWD3038254948.212.472.5127.9
Model Y Standard RWD (18in Wheels)2448325776.710.159.3107.7
Model Y Long Range RWD2546305897.811.768.7108.9
Model Y Standard AWD2644295766.610.158.889.6
Model Y Standard RWD (19in Wheels)2644295796.910.460.6107.9
Model Y Long Range AWD2743285887.711.667.9811.0
Model Y Performance AWD3236244988.512.975.312.28.0
Model S27432851119.614.685.29.711.4
Model S Plaid31372541149.91587.8129.5
Model S Plaid (21in wheels)36322141119.714.685.6129.3
Model X32362441139.814.886.6148.0
Model X Plaid34342241149.91587.6129.5
Cybertruck AWD432718314012.218.4107.511.711.9
Cybertruck Dual Motor AWD432718314012.218.4107.51211.6
Cybertruck Long Range (20in Cyber wheels)432718314412.519110.81212.0

EPA kWh per 100 miles and range: the EPA vehicle dataset on fueleconomy.gov (file dated 2026-09-29, fetched 2026-10-24). kWh empty to full = EPA range x EPA kWh per 100 miles / 100. Hours = that kWh / kW, at a steady rate, if the car accepts the rate. The last two columns are EPA's own time to charge at 240 V and the average it implies (full charge kWh / EPA hours). EPA does not state the charger it used; where its hours are well above the hours at 11.5 kW, the trim likely draws less than 11.5 kW, as Tesla's manual warns some cars do. Open data: epa-years.csv. Electricity: EIA Electric Power Monthly table 5.6.B, residential sector, year to date through August 2026, released 2026-10-23.

What this leaves out

Hours from EPA's own 240 V test for every model year: how long to charge a Tesla. What the electricity costs: home charging cost by state.

Questions

How many amps should I charge my Tesla at?

A Tesla draws what the charger offers, up to the limit of its own onboard charger. Tesla's manuals list the most each setup supplies: the Wall Connector 48 amps on a 60 amp breaker, 40 on 50, 32 on 40, 24 on 30, 16 on 20, 12 on 15; the Mobile Connector 32 amps on a NEMA 14-50 and 12 on a 120 V outlet. Tesla's Wall Connector manual says "Some Tesla vehicles may draw less current than the max output." Fewer amps means a slower charge; at home the price per kWh is the same at any speed.

What size breaker does a Tesla Wall Connector need?

Tesla's Gen 3 Wall Connector manual: "For maximum power output, install a standard double pole 60 amp circuit breaker", which gives 48 amps and 11.5 kW. Smaller breakers give less: 50 amp breaker, 40 amps, 9.6 kW; 40 amp breaker, 32 amps, 7.6 kW; 30 amp breaker, 24 amps, 5.7 kW; 20 amp breaker, 16 amps, 3.8 kW; 15 amp breaker, 12 amps, 2.8 kW. The Wall Connector has GFCI protection built in, and the manual says "do not install a GFCI circuit breaker". For maximum power it calls for minimum 6 AWG copper rated 90 C. The breaker size is set when the Wall Connector is commissioned. In Tesla's table the maximum output is 80 percent of the breaker rating at every size. An electrician sizes the circuit for your panel and local code.

How fast does a Tesla Wall Connector charge?

At its maximum, 48 amps and 11.5 kW, a Wall Connector adds about 27 to 48 miles of EPA range per hour to a 2026 Tesla if the car accepts that rate; by model: Model 3 38 to 48; Model Y 36 to 48; Model S 32 to 43; Model X 34 to 36; Cybertruck 27. From empty to the full EPA range that is about 6.6 to 12.5 hours at 11.5 kW. These are kW x 100 / EPA kWh per 100 miles, not Tesla figures. EPA's own 240 V times for 2026 Teslas, 8 to 14 hours, average 6.4 to 12.0 kW, so some trims charge slower than the Wall Connector's maximum; each trim's EPA hours are in the table on this page.

Wall Connector or Mobile Connector: which charges faster?

The Wall Connector supplies up to 11.5 kW (48 amps on a 60 amp breaker) and the Mobile Connector on a NEMA 14-50 outlet 7.6 kW (32 amps), per Tesla's manuals. For a 2026 Model Y that is about 36 to 48 against 24 to 32 miles of EPA range per hour, and 6.6 to 8.5 against 10.1 to 12.9 hours from empty to full, if the car accepts the full rate. The Mobile Connector plugs into an outlet and its manual lists a 1.3 kW, 12 amp rate on a 120 V outlet too.

How fast does a Tesla charge on a NEMA 14-50 outlet?

Tesla's Mobile Connector manual lists 32 amps and 7.6 kW with its 14-50 adapter (the same for a 6-50 outlet). That adds about 18 to 32 miles of EPA range per hour to a 2026 Tesla if the car accepts the rate (Model 3 25 to 32, Model Y 24 to 32), and a full charge from empty takes about 10.1 to 19 hours. The connector "automatically detects the attached adapter" and sets the current.

How fast does a Tesla charge on a 120 V outlet?

Tesla's Mobile Connector manual lists 12 amps and 1.3 kW on a standard 120 V outlet (NEMA 5-15), and 16 amps and 1.7 kW on a 5-20 outlet. On a 5-15 that adds about 3 to 5 miles of EPA range per hour to a 2026 Tesla, so a full charge from empty takes about 58.8 to 110.8 hours. EPA lists no 120 V charge time for any Tesla; these are estimates from Tesla's kW and EPA's ratings.

How many miles per hour does a Tesla charge at 16, 24, 32, 40 and 48 amps?

For a 2026 Model Y at 240 V, if the car accepts the rate, using Tesla's kW for each Wall Connector setting: 48 amps (11.5 kW) about 36 to 48 miles of range per hour; 40 amps (9.6 kW) about 30 to 40 miles of range per hour; 32 amps (7.6 kW) about 24 to 32 miles of range per hour; 24 amps (5.7 kW) about 18 to 24 miles of range per hour; 16 amps (3.8 kW) about 12 to 16 miles of range per hour. A Model 3 adds 38 to 48 miles per hour at 48 amps.

What is the fastest a Tesla can charge at home?

Tesla's Gen 3 Wall Connector manual lists an output range of 12 to 48 amps, so 11.5 kW at 240 V is the most it supplies. The car's onboard charger can set a lower limit. EPA's dataset lists an optional higher power charger (a 72 amp option or an 80 amp dual charger) for some Tesla trims from 2014 to 2023, with its own charge time. Superchargers are DC fast chargers and are not covered here.

Why does my Tesla charge slower than the Wall Connector's rating?

Three things in Tesla's manuals: the car's onboard charger ("Some Tesla vehicles may draw less current than the max output"), the breaker size set when the Wall Connector was commissioned, and temperature ("Charge time also depends on ambient temperature" and the battery's temperature, per the Mobile Connector manual). A Wall Connector sharing power with others also splits the site's current.

Can two Teslas share Wall Connector power?

Yes, with power sharing. Tesla's Wall Connector manual says each Wall Connector needs its own branch circuit and the units "distribute power based on the total power allocated to the site", up to 16 Wall Connectors. Each gets the available continuous amps divided by the number in use, up to 48 amps when it is the only one charging.

Related: Wall Connector and NEMA 14-50 install cost, every install cost row, charging time at 240 V for every model year, full charge cost by trim and state, range for every model year, Tesla vs gas savings by state, charging cost by model (Model 3, Model Y, Model S, Model X, Cybertruck) and the 5-year cost calculator.